BYLRT - FLUID CALIBRATION

Product Identification

Product ID:FLUID CALIBRATION
MSDS Date:06/13/1995
FSC:9150
NIIN:00F045485
MSDS Number: BYLRT

Responsible Party
SOLVENTS AND CHEMICALS INC
4704 SHANK RD
PEARLAND, TX 77588-0490
US

Emergency Phone: 713-485-5377

Info Phone: 713-485-5377

Cage: 4W432

Contractor
SOLVENTS AND CHEMICALS, INC.
PEARLAND, TX 77588-0490 US

Telephone: 281-485-5377

Cage: 4W432

Ingredients

POLYCYCLIC AROMATICS

Fraction By Weight: <0.1%


BENZENE (SUSPECTED HUMAN CARC BY ACGIH, IARC, ANIMAL

CAS: 71-43-2

RTECS: CY1400000

Fraction By Weight: <0.001%

ACGIH TLV: 0.3 MG/CUM (A2) IC

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: ANESTHETIC, IRRITATION TO
RESPIRATORY TRACT, NERVOUS SYSTEM DEPRESSION, VAPOR HARMFUL. EYES:
IRRITATION. SKIN: IRRITATION, DERMATITIS. INGESTION: HARMFUL/FATAL,
CAN CAUSE ABDOMINAL IRRITAT ION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, DEFATTING, REDNESS, TEARING,
BLURRED VISION, ANESTHETIC, NAUSEA, VOMITING & DIARRHEA.
Medical Cond Aggravated by Exposure:PERSONS W/SEVERE SKIN, LIVER/KIDNEY
PROBLEMS.

First Aid

First Aid:EYES: FLUSH W/PLENTY OF WATER FOR 15 MIN. SKIN: WASH W/SOAP &
WATER. INHALATION: MOVE TO FRESH AIR. IF BREATHING IS DIFFICULT
GIVE OXYGEN. IF BREATHING HAS STOPPED GIVE CPR. INGESTION: DON'T
INDUCE VO MITING. HAVE PATIENT LIE DOWN & KEEP WARM. VOMITING MAY
LEAD TO PNEUMONITIS, WHICH MAY BE FATAL. OBTAIN MEDICAL ATTENTION
IN ALL CASES.

Fire Fighting

Flash Point Method:TCC
Flash Point:100-140F
Lower Limits:1
Extinguishing Media:CO2/FOAM
Fire Fighting Procedures:USE WATER SPRAY TO COOL CLOSED CONTAINERS & TO
PROTECT FIREFIGHTERS. USE FOG NOZLES IF WATER IS USED. NIOSH
APPPROVED POSITIVE-PRESSURE SCBA.
Unusual Fire/Explosion Hazard:MATERIAL IS COMBUSTIBLE. CLOSED
CONTAINERS MAY EXPLODE IF EXPOSED TO EXTREME HEAT. AUTOIGNITION
TEMP: 533F.

Accidental Release

Spill Release Procedures:STOP AT SOURCE. DIKE AREA & CONTAIN. CLEAN UP
REMAINDE R W/ABSORBENT MATERIALS. MOP UP & DISPOSE OF.

Handling

Handling and Storage Precautions:ISOLATE FROM OXIDIZERS, HEAT & OPEN
FLAME. USE ONLY W/ADEQUATE VENTILATION. AVOID BREATHING OF
VAPOR/SPRAY MIST & SKIN CONTACT.
Other Precautions:AVOID FREE FALL OF LIQUID. GROUND CONTAINERS WHEN
TRANSFERRING. DON'T FLAME CUT, BRAZE/WELD. EMPTY CONTAINER IS
HAZARDOUS. DON'T STORE >120F. STORE LARGE AMOUNTS IN STRUCTURES
MADE FOR OSHA CLASS II L IQUIDS. (SEE SUPP)

Exposure Controls

Respiratory Protection:APPLYING TO HOT SURFACES REQUIRES SPECIAL
PRECAUTIONS. IF >TLV USE NIOSH APPROVED POSITIVE-PRESSURE SCBA.
Ventilation:LOCAL EXHAUST: REQUIRED. MECHANICAL (GENERAL): ACCEPTABLE.
USE EXPLOSION-PROOF EQUIPMENT.
Protective Gloves:REQUIRED
Eye Protection:GOGGLES/FACE SHIELD
Other Protective Equipment:APRON & FOOTWEAR IMPERVIOUS TO MATERIAL.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
OTHER PRECAUTIONS CONT'D: KEEP CONTAINER TIGHTLY CLOSED & UPRIGHT.

Chemical Properties

Boiling Pt:B.P. Text:310-353F
Vapor Pres:3.1
Vapor Density:4.5
Spec Gravity:0.779
VOC Pounds/Gallon:765
Solubility in Water:NEGLIGIBLE
Appearance and Odor:LIQUID, WATER-WHITE W/AROMATIC ODOR
Percent Volatiles by Volume:98.2

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS SUCH AS PERMANGANATES, CHROMATES & PEROXIDES.
Stability Condition to Avoid:HEAT & OPEN FLAME.
Hazardous Decomposition Products:CO, CO2 FROM BURNING.

Disposal

Waste Disposal Methods:RECYCLE/DISPOSE OF IAW/LOCAL, STATE & FEDERAL
REGULATIONS. COMBUSTIBLE LIQUID UN1268.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.